Cogo cannulated Headless stupra

Description:


Product Detail

Product Tags

Product nomen:Φ2.4 Cannulated Pressio Headless Screw

Materia:Titanium alloy

Diameter:2.4mm

Product speciem

d*

Item No.

Specification

11.08.0424.008313

2.4*8mm

11.08.0424.009313

2.4*9mm

11.08.0424.010313

2.4*10mm

11.08.0424.011313

2.4*11mm

11.08.0424.012313

2.4*12mm

11.08.0424.013313

2.4*13mm

11.08.0424.014313

2.4*14mm

11.08.0424.016313

2.4*16mm

11.08.0424.018313

2.4*18mm

11.08.0424.020313

2.4*20mm

11.08.0424.022313

2.4*22mm

11.08.0424.024313

2.4*24mm

11.08.0424.026313

2.4*26mm

11.08.0424.028313

2.4*28mm

11.08.0424.030313

2.4*30mm

Indicatio:

Available cum brevibus et longis filorum longis ad indicia tractanda amplis.

2.4mm Compressio sine capite Cochleas destinantur ad fixationem fracturae intra-articularis et extra articularis et nonuniones ossium parvi et fragmentorum ossis parvi;arthrodeses articulis parvis;bunionectomia et osteotomia, inter scaphoida et alia ossa carpalia, metacarpalia, tarsalia, metatarsalia, patella, styloides ulnaris, capitellum, caput radiale et styloideum radiale.

Features & Beneficia:

Electa importata nativus medicinae Titanium mixturae vectis, ad summam duritiem et mollitiem consequendam

Classis mundi Helvetica CNC latae longitudinalis torno secans, machinae unum tempus

Screw superficies technologiam unicam anodientem capere, potest augere cochleae superficiem duritiem et resistentiam laesuram

Matching instruments:

Φ0.9 Threaded acus

Φ1.7 Cannulated medicinae terebro frenum

SW1.5 solus Cannulated hexagonum

Product nomen:Φ2.7 Cannulated Pressio Headless Screw

Materia:Titanium alloy

Diameter:2.7mm

Product speciem

5

Item No.

Specification

11.08.0427.008313

2.7*8mm

11.08.0427.009313

2.7*9mm

11.08.0427.010313

2.7*10mm

11.08.0427.011313

2.7*11mm

11.08.0427.012313

2.7*12mm

11.08.0427.013313

2.7*13mm

11.08.0427.014313

2.7*14mm

11.08.0427.016313

2.7*16mm

11.08.0427.018313

2.7*18mm

11.08.0427.020313

2.7*20mm

11.08.0427.022313

2.7*22mm

11.08.0427.024313

2.7*24mm

11.08.0427.026313

2.7*26mm

11.08.0427.028313

2.7*28mm

11.08.0427.030313

2.7*30mm

Indicatio:

Available cum brevibus et longis filorum longis ad indicia tractanda amplis.

Features & Beneficia:

Electa importata nativus medicinae Titanium mixturae vectis, ad summam duritiem et mollitiem consequendam

Classis mundi Helvetica CNC latae longitudinalis torno secans, machinae unum tempus

Screw superficies technologiam unicam anodientem capere, potest augere cochleae superficiem duritiem et resistentiam laesuram

Matching instruments:

Φ0.9 Threaded acus

Φ1.9 Cannulatae medicinae terebro frenum

SW1.5 solus Cannulated hexagonum

Product nomen:Φ3.0 Cannulated Pressio Headless Screw

Materia:Titanium alloy

Diameter:3.0mm

Product speciem

3

Item No.

Specification

11.08.0430.016313

3.0*16mm

11.08.0430.018313

3.0*18mm

11.08.0430.020313

3.0*20mm

11.08.0430.022313

3.0*22mm

11.08.0430.024313

3.0*24mm

11.08.0430.026313

3.0*26mm

11.08.0430.028313

3.0*28mm

11.08.0430.030313

3.0*30mm

11.08.0430.032313

3.0*32mm

11.08.0430.034313

3.0*34mm

11.08.0430.036313

3.0*36mm

11.08.0430.038313

3.0*38mm

11.08.0430.040313

3.0*40mm

Indicatio:

Available cum brevibus et longis filorum longis ad indicia tractanda amplis.

3.0mm Compressio sine capite Cochleas destinantur ad fixationem fracturae intra-articularis et extra articularis et nonuniones ossium parvi et fragmentorum ossis parvi;arthrodeses articulis parvis;bunionectomia et osteotomia, inter scaphoida et alia ossa carpalia, metacarpalia, tarsalia, metatarsalia, patella, styloides ulnaris, capitellum, caput radiale et styloideum radiale.

Features & Beneficia:

Electa importata nativus medicinae Titanium mixturae vectis, ad summam duritiem et mollitiem consequendam

Classis mundi Helvetica CNC latae longitudinalis torno secans, machinae unum tempus

Screw superficies technologiam unicam anodientem capere, potest augere cochleae superficiem duritiem et resistentiam laesuram

Matching instruments:

Φ1.1 Threaded acus

Φ2.1 Cannulatae medicinae terebro frenum

SW2.0 Cannulated hexagonum solus

Product nomen:Φ3.5 Cannulated Pressio Headless Screw

Materia:Titanium alloy

Diameter:3.5mm

Product speciem

4

Item No.

Specification

11.08.0435.020313

3.5*20mm

11.08.0435.022313

3.5*22mm

11.08.0435.024313

3.5*24mm

11.08.0435.026313

3.5*26mm

11.08.0435.028313

3.5*28mm

11.08.0435.030313

3.5*30mm

11.08.0435.032313

3.5* 32mm

11.08.0435.034313

3.5*34mm

11.08.0435.036313

3.5*36mm

11.08.0435.038313

3.5*38mm

11.08.0435.040313

3.5*40mm

11.08.0435.042313

3.5*42mm

11.08.0435.044313

3.5*44mm

11.08.0435.046313

3.5*46mm

11.08.0435.048313

3.5*48mm

11.08.0435.050313

3.5*50mm

Indicatio:

Available cum brevibus et longis filorum longis ad indicia tractanda amplis.

3.5mm Compressio sine capite Cochleas destinantur ad fixationem fracturae intra-articularis et extra articularis et nonuniones ossium parvorum et fragmentorum ossis parvi;arthrodeses articulis parvis;bunionectomia et osteotomia, inter scaphoida et alia ossa carpalia, metacarpalia, tarsalia, metatarsalia, patella, styloides ulnaris, capitellum, caput radiale et styloideum radiale.

Features & Beneficia:

Electa importata nativus medicinae Titanium mixturae vectis, ad summam duritiem et mollitiem consequendam

Classis mundi Helvetica CNC latae longitudinalis torno secans, machinae unum tempus

Screw superficies technologiam unicam anodientem capere, potest augere cochleae superficiem duritiem et resistentiam laesuram

Matching instruments:

Φ1.1 Threaded acus

Φ2.5 Cannulated medicinae terebro frenum

SW2.0 Cannulated hexagonum solus

Product nomen:Φ4.0 Cannulated Pressio Headless Screw

Materia:Titanium alloy

Diameter:4.0mm

Product speciem

2

Item No.

Specification

11.08.0440.020313

4.0*20mm

11.08.0440.022313

4.0*22mm

11.08.0440.024313

4.0*24mm

11.08.0440.026313

4.0*26mm

11.08.0440.028313

4.0*28mm

11.08.0440.030313

4.0*30mm

11.08.0440.032313

4.0*32mm

11.08.0440.034313

4.0*34mm

11.08.0440.036313

4.0*36mm

11.08.0440.038313

4.0*38mm

11.08.0440.040313

4.0*40mm

11.08.0440.042313

4.0*42mm

11.08.0440.044313

4.0*44mm

11.08.0440.046313

4.0*46mm

11.08.0440.048313

4.0*48mm

11.08.0440.050313

4.0*50mm

Indicatio:

Available cum brevibus et longis filorum longis ad indicia tractanda amplis.

Features & Beneficia:

Electa importata nativus medicinae Titanium mixturae vectis, ad summam duritiem et mollitiem consequendam

Classis mundi Helvetica CNC latae longitudinalis torno secans, machinae unum tempus

Screw superficies technologiam unicam anodientem capere, potest augere cochleae superficiem duritiem et resistentiam laesuram

Matching instruments:

Φ1.5 Threaded acus

Φ2.7 Cannulated medicinae terebro frenum

SW2.5 egeo Cannulated hexagonum

Ratio cochleae cannulatae destinatur ad fractiones, fusiones, et osteotomias magnarum et parvarum ossium et cochleis et lavatoribus constat.

Praecipua utilitas cochlearum cannulatorum est ut in filum duce vel duce acum inseri possint.Diameter paxillus rectoris multo minor est cochleae cannulatae et accuratius utens fluoroscopia in cella operativa collocari potest.Praeterea, data eius parva diametro, dux clavum pluries innovari potest, si ad accuratam collocationem necessariam sine nimia ossis iactura sit.

Cum diametris ab 2.4 ad -7.3, cochleis cannulatis amplis indiciis tegunt et solatium chirurgi adiciunt cum longitudinibus stamina diversis quae permittunt ut cochleae lagani aptam eligat pro fractura data.

Omnes cochleae cannulatae sunt ad usum duce filum.Quaelibet cochlea partim vel omnino lina utens cancellosa dente forma.Cochleae osseae cannulatae communiter sunt in pelvi, coxae, genu, talo, et pede.Fracturae colli femoris, disruptiones sacroiliacae iuncturae, tibialis planities et fracturae femoris intercondylaris, fracturae calcaneae, fracturae talaris, arthrodesis talaris, arthrodesis subtalaris, fractura femoris distalis, et applicatio humeralis, olecranon.

Cochleae cannulatae sunt ut in filo duce adhibeantur et singulae cochleae vel ex parte vel plene lina utentes formam filo cancelloso.Cannulation destinatur ad insertionem percutaneo minime incursivam.Cochleae stamineae ex parte unum fragmentum ossis alteri decedere possunt, ubi fragmentum ossis longe a filis cochleae capitur et ad fragmentum cortex prope trahitur a parte capitis cochleae.Cochleae plene stamineae destinatae sunt ad fracturas stabiliendas cum paulo ad nullam compressionem per fracturam faciendam.

Increscens sumptus valetudinis et cum solutione systemata ducit ad optiones sumptus parvos sicut cochleae cannulatae.In fracturae non-expositis, cochleae eventus clinicos praebere possunt melioribus optionibus sumptus pares.

Irritatio mollis textus ad vexillum reducere capita cochleae ordinatur.

Cochleae auto-Tapping frenum ordinatur ad insertionem cochleae faciliorem et necessitatem tollendam in aliquibus casibus percutiendo.


  • Previous:
  • Deinde: