Manufactur standard Lcp Fracture Plate - Pelvic Reconstruction Locking Plate – Shuangyang Detail:
Pelvic Reconstruction Locking Plate
—- Straight Reconstruction Locking Plate
Pelvic reconstruction locking plate implant we have straight reconstruction locking plate and arc reconstruction locking plate to meet the clinic choose.
Features:
1. Surface anodized;
2. Anatomical shape design;
3. Titanium material and advanced processing technology;
4. Low profile design helps reduce soft tissue irritation;
5. Round hole can be choosing both locking screw and cortex screw;
Indication:
Titanium pelvic reconstruction locking plate is suitable for acetabulum and pelvic fracture.
Used for Φ40 locking screw, Φ4.0 cancellous screw, matched with 4.0 series medical instrument set.
Titanium Straight Reconstruction Locking Plate Specification
Order code |
Specification |
|
10.11.07.06030000 |
Straight reconstruction 6 Holes |
72mm |
10.11.07.07030000 |
Straight reconstruction 7 Holes |
84mm |
*10.11.07.08030000 |
Straight reconstruction 8 Holes |
96mm |
10.11.07.09030000 |
Straight reconstruction 9 Holes |
108mm |
10.11.07.10030000 |
Straight reconstruction 10 Holes |
120mm |
10.11.07.12030000 |
Straight reconstruction 12 Holes |
144mm |
Pelvic Reconstruction Locking Plate
—- Arc Reconstruction Locking Plate
Pelvic reconstruction locking plate implant we have straight reconstruction locking plate and arc reconstruction locking plate to meet the clinic choose.
Features:
1. Surface anodized;
2. Anatomical shape design;
3. Titanium material and advanced processing technology;
4. Low profile design helps reduce soft tissue irritation;
5. Round hole can be choosing both locking screw and cortex screw;
Indication:
Titanium pelvic reconstruction locking plate is suitable for acetabulum and pelvic fracture.
Used for Φ40 locking screw, Φ4.0 cancellous screw, matched with 4.0 series surgical instrument set.
Titanium Arc Reconstruction Locking Plate Specification
Order code |
Specification |
|
*10.11.07.06031000 |
Arc reconstruction 6 Holes |
69mm |
10.11.07.08031000 |
Arc reconstruction 8 Holes |
89mm |
10.11.07.10031000 |
Arc reconstruction 10 Holes |
107mm |
10.11.07.12031000 |
Arc reconstruction 12 Holes |
122mm |
10.11.07.14031000 |
Arc reconstruction 14 Holes |
133mm |
10.11.07.16031000 |
Arc reconstruction 16 Holes |
139mm |
Pelvic Reconstruction Locking Plate
—- Straight Reconstruction Locking Plate II Type
Titanium pelvic reconstruction locking plate we have straight reconstruction locking plate and arc reconstruction locking plate can be choose.
Features:
1. Surface anodized;
2. Anatomical shape design;
3. Titanium material and advanced processing technology;
4. Low profile design helps reduce soft tissue irritation;
5. Round hole can be choosing both locking screw and cortex screw;
Indication:
Titanium pelvic reconstruction locking plate is suitable for acetabulum and pelvic fracture.
Used for Φ40 locking screw, Φ4.0 cancellous screw, matched with 4.0 series orthopedic instrument set
Titanium Straight Reconstruction Locking Plate II type Specification
Order code |
Specification |
|
10.11.07.06030002 |
Straight reconstruction 6 Holes |
72mm |
10.11.07.07030002 |
Straight reconstruction 7 Holes |
84mm |
*10.11.07.08030002 |
Straight reconstruction 8 Holes |
96mm |
10.11.07.09030002 |
Straight reconstruction 9 Holes |
108mm |
10.11.07.10030002 |
Straight reconstruction 10 Holes |
120mm |
10.11.07.12030002 |
Straight reconstruction 12 Holes |
144mm |
Pelvic Reconstruction Locking Plate
—- Arc Reconstruction Locking Plate II Type
Orthopedic implant of pelvic reconstruction locking plate is titanium with straight reconstruction locking plate and arc reconstruction locking plate can be choose.
Features:
1. Titanium material and advanced processing technology;
2. Low profile design helps reduce soft tissue irritation;
3. Surface anodized;
4. Anatomical shape design;
5. Round hole can be choosing both locking screw and cortex screw;
Indication:
Pelvic reconstruction titanium locking plate implant is suitable for acetabulum and pelvic fracture.
Used for Φ40 locking screw, Φ4.0 cancellous screw, matched with 4.0 series trauma instrument set
Titanium Arc Reconstruction Locking Plate II type Specification
Order code |
Specification |
|
10.11.07.06031002 |
Arc reconstruction 6 Holes |
71mm |
*10.11.07.080131002 |
Arc reconstruction 8 Holes |
92mm |
10.11.07.10031002 |
Arc reconstruction 10 Holes |
110mm |
10.11.07.12031002 |
Arc reconstruction 12 Holes |
124mm |
10.11.07.14031002 |
Arc reconstruction 14 Holes |
134mm |
10.11.07.16031002 |
Arc reconstruction 16 Holes |
140mm |
Product detail pictures:
Related Product Guide:
Our firm since its inception, normally regards item top quality as company life, constantly make improvements to generation technology, improve product excellent and repeatedly strengthen organization total good quality management, in strict accordance with the national standard ISO 9001:2000 for Manufactur standard Lcp Fracture Plate - Pelvic Reconstruction Locking Plate – Shuangyang, The product will supply to all over the world, such as: Zambia, Rotterdam, Barbados, Our items have national accreditation requirements for qualified, high quality products, affordable value, was welcomed by people today all over the world. Our goods will continue to enhance within the order and look forward to cooperation with you, Should any of these products be of interest to you, please letus know. We are going to be content to offer you a quotation up on receipt of your detailed needs.
By Amy from Kyrgyzstan - 2017.11.20 15:58
Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.
By Cindy from Maldives - 2018.05.13 17:00