Orthodontic Ligation Nail 1.6 Self Drilling & Tapping

Application

Design for maxillofacial trauma fracture surgical treatment, used for nasal part, pars orbitalis, pars zygomatica, maxlla region, mandible (simple and stable trauma).

Material: medical titanium alloy

Diameter: 1.6mm

Product specification

Item No.

Specification

10.07.0516.006115

1.6*6mm

10.07.0516.007115

1.6*7mm

Features & Benefits:

 used for orthodontic anchorage and intermaxilary ligation.

 the head of screw has two cross holes, easy to insert wire.

 square screw head design ensures better holding and torque force, easier to screw in.

Matching instrument:

medical drill bit φ1.4*5*95mm (for harder cortical bone)

orthodontic screw driver: SW2.4

broken nail extractorφ2.0

straight quick coupling handle

The method of ligation and fixation between small annular jaws is suitable for:

1. Single linear fracture of mandible body without obvious displacement.

2. The benign tumor of the mandibular body or chin was removed and bone grafted immediately.

3. Comprehensive auxiliary fixation of mandibular defects after firearm injury by bone grafting.

Early reduction, fixation and functional motor therapy are the three principles for the definitive treatment of limb fractures.Jaw bone fracture treatment principle, have their similarities and differences, the upper jaw fractures, because its the muscles of the bone surface attachment, in addition to the wing of internal and external muscle, more for the expression of some weak muscle, as long as the teeth can return to normal relations, judge fracture section have been reset, then select the fixed methods of fracture fixed in the base of skull.And mandible fracture because of the strong masticatory muscles pull can cause obvious dislocation, the method of fixed jaw fracture must be more stable, at the same time take into account the temporomandibular joint of early functional exercise, active and painless activity can promote the blood supply of bone and soft tissue, synovial fluid promotes the articular cartilage nutrition, combined with partial weight-bearing, prevent muscle disuse atrophy, joint stiffness, etc., therefore, the treatment of mandibular fracture guidelines, aspires to the three principles.

Restoring occlusion is the goal of treatment. Jawbone fracture is different from long tube fracture, its significant particularity, that is, there is a row of arch dentition on the body of the jaw, and the formation of a normal occlusal relationship between the upper and lower mandibles, managing the masticatory function.Whether the occlusal relationship of upper and lower teeth can be restored is one of the most important indicators to evaluate the treatment effect of jaw fracture.The teeth on the bone segment are often used as a support or anchor base for reduction and fixation by ligating arch splints or other intraoral splints.In the case of non-firearm injuries, it is recommended that the teeth at the fracture line should be preserved as far as possible.If the root is broken, the tooth is extremely loose, the fracture line is impacted through the third mandibular molar or the tooth is embedded, the tooth should be removed.For jaw firearm injury, more to cherish the alveolar process of the remaining teeth, should be restored and retained by every means possible, the crown is broken but there is a strong root, especially after the fracture section of the strong root, can be used for root canal treatment, but also conducive to as a post nail or cover the fixation of the brackets.

Up to 50–70% of people who survive traffic accidents suffer from facial trauma. In most developed countries, violence from other people has replaced vehicle collisions as the main cause of maxillofacial trauma; In the case of developing countries traffic accidents are still the major cause. Seatbelt and airbag have been used to reduce the incidence of maxillofacial trauma, but fractures of the mandible, namely the jawbone, are not decreased by these protective measures. Using of motorcycle helmets can decrease maxillofacial trauma efficiently.

Maxillofacial fractures are distributed in a fairly normal curve by age, with a peak incidence occurring between ages 20 and 40, and children under 12 suffering only 5–10% of all maxillofacial fractures. Most maxillofacial trauma in children involves lacerations and soft tissue injuries. There is a lower proportion of cortical bone to cancellous bone in children’s faces, poorly developed sinuses make the bones stronger, and fat pads provide protection for the facial bones.

Head and brain injuries are commonly associated with maxillofacial trauma, particularly that of the upper face; brain injury occurs in 15–48% of people with maxillofacial trauma. Coexisting injuries can affect treatment of facial trauma; for example they may be emergent and need to be treated before facial injuries. People with trauma above the level of the collar bones are considered to be at high risk for cervical spine injuries (spinal injuries in the neck) and special precautions must be taken to avoid movement of the spine, which could worsen a spinal injury.

plane

SUBSCRIBE & BE UP TO DATE

For inquiries about our products or pricelist,please leave to us and we will be in touch within 24 hours.

Common Questions About
Medical Instrument

Need More Answers?

Are you manufacturer or reseller?

We are manufacturer who has more than 20 years experience on research & design, production and sale.

We have passed CE, ISO13485, ISO9001 certification. From production to delivery, each piece of products will be strictly inspected more than 5 times. If you need, we accept you to let a third-party inspection company to conduct product quality.

We have our own design department which accept customized services, welcome you contact us to develop new products.

Yes sure, small order are also welcomed.

We will issue Proforma Invoice for you after noting the exact product and quantity you need, to pay via T/T, PayPal, Western Union, etc. We also support Alibaba online trade assurance order.

Sample order will be sent within 3 days after receiving sample fee. 3-15 days for general order according to the quantity. Customized order need mutual negotiation.

Sure, We warmly welcome you visit us. Our factory is located in Zhangjiagang City, Jiangsu Province.

Contact Us

Pease allowup to 24hrs.Our agent wilcontact youas soon as possible.