Straight-Reconstruction-Locking-Plate-II-Type1 Arc-Reconstruction-Locking-Plate1 Arc-Reconstruction-Locking-Plate-II-Type1 132

Pelvic Reconstruction Locking Plate

Medical implants of clavicle reconstruction locking plate provide middle and distal clavicle fracture.

Pelvic Reconstruction Locking Plate

—- Straight Reconstruction Locking Plate

Pelvic reconstruction locking plate implant we have straight reconstruction locking plate and arc reconstruction locking plate to meet the clinic choose.

  

Features:  

1. Surface anodized;
2. Anatomical shape design;
3. Titanium material and advanced processing technology;
4. Low profile design helps reduce soft tissue irritation;
5. Round hole can be choosing both locking screw and cortex screw;

Indication:

Titanium pelvic reconstruction locking plate is suitable for acetabulum and pelvic fracture.

Used for Φ40 locking screw, Φ4.0 cancellous screw, matched with 4.0 series medical instrument set.

Titanium Straight Reconstruction Locking Plate Specification

Order code

Specification

10.11.07.06030000

Straight reconstruction 6 Holes

72mm

10.11.07.07030000

Straight reconstruction 7 Holes

84mm

*10.11.07.08030000

Straight reconstruction 8 Holes

96mm

10.11.07.09030000

Straight reconstruction 9 Holes

108mm

10.11.07.10030000

Straight reconstruction 10 Holes

120mm

10.11.07.12030000

Straight reconstruction 12 Holes

144mm

Pelvic Reconstruction Locking Plate

—- Arc Reconstruction Locking Plate

Pelvic reconstruction locking plate implant we have straight reconstruction locking plate and arc reconstruction locking plate to meet the clinic choose.

Features:  

1. Surface anodized;
2. Anatomical shape design;
3. Titanium material and advanced processing technology;
4. Low profile design helps reduce soft tissue irritation;
5.  Round hole can be choosing both locking screw and cortex screw;

Indication:

Titanium pelvic reconstruction locking plate is suitable for acetabulum and pelvic fracture.

Used for Φ40 locking screw, Φ4.0 cancellous screw, matched with 4.0 series surgical instrument set.

Titanium Arc Reconstruction Locking Plate Specification

Order code

Specification

*10.11.07.06031000

Arc reconstruction 6 Holes

69mm

10.11.07.08031000

Arc reconstruction 8 Holes

89mm

10.11.07.10031000

Arc reconstruction 10 Holes

107mm

10.11.07.12031000

Arc reconstruction 12 Holes

122mm

10.11.07.14031000

Arc reconstruction 14 Holes

133mm

10.11.07.16031000

Arc reconstruction 16 Holes

139mm

Pelvic Reconstruction Locking Plate

—- Straight Reconstruction Locking Plate II Type

Titanium pelvic reconstruction locking plate we have straight reconstruction locking plate and arc reconstruction locking plate can be choose.

Features:  

1. Surface anodized;
2. Anatomical shape design;
3. Titanium material and advanced processing technology;
4. Low profile design helps reduce soft tissue irritation;
5.  Round hole can be choosing both locking screw and cortex screw;

Indication:

Titanium pelvic reconstruction locking plate is suitable for acetabulum and pelvic fracture.

Used for Φ40 locking screw, Φ4.0 cancellous screw, matched with 4.0 series orthopedic instrument set

Titanium Straight Reconstruction Locking Plate II type Specification

Order code

Specification

10.11.07.06030002

Straight reconstruction 6 Holes

72mm

10.11.07.07030002

Straight reconstruction 7 Holes

84mm

*10.11.07.08030002

Straight reconstruction 8 Holes

96mm

10.11.07.09030002

Straight reconstruction 9 Holes

108mm

10.11.07.10030002

Straight reconstruction 10 Holes

120mm

10.11.07.12030002

Straight reconstruction 12 Holes

144mm

Pelvic Reconstruction Locking Plate

—- Arc Reconstruction Locking Plate II Type

Orthopedic implant of pelvic reconstruction locking plate is titanium with straight reconstruction locking plate and arc reconstruction locking plate can be choose.

Features:  

1. Titanium material and advanced processing technology;

2.  Low profile design helps reduce soft tissue irritation;

3.  Surface anodized;

4.  Anatomical shape design;

5.  Round hole can be choosing both locking screw and cortex screw;

Indication:

Pelvic reconstruction titanium locking plate implant is suitable for acetabulum and pelvic fracture.

Used for Φ40 locking screw, Φ4.0 cancellous screw, matched with 4.0 series trauma instrument set

Titanium Arc Reconstruction Locking Plate II type Specification

Order code

Specification

10.11.07.06031002

Arc reconstruction 6 Holes

71mm

*10.11.07.080131002

Arc reconstruction 8 Holes

92mm

10.11.07.10031002

Arc reconstruction 10 Holes

110mm

10.11.07.12031002

Arc reconstruction 12 Holes

124mm

10.11.07.14031002

Arc reconstruction 14 Holes

134mm

10.11.07.16031002

Arc reconstruction 16 Holes

140mm

plane

SUBSCRIBE & BE UP TO DATE

For inquiries about our products or pricelist,please leave to us and we will be in touch within 24 hours.

Common Questions About
Medical Instrument

Need More Answers?

Are you manufacturer or reseller?

We are manufacturer who has more than 20 years experience on research & design, production and sale.

We have passed CE, ISO13485, ISO9001 certification. From production to delivery, each piece of products will be strictly inspected more than 5 times. If you need, we accept you to let a third-party inspection company to conduct product quality.

We have our own design department which accept customized services, welcome you contact us to develop new products.

Yes sure, small order are also welcomed.

We will issue Proforma Invoice for you after noting the exact product and quantity you need, to pay via T/T, PayPal, Western Union, etc. We also support Alibaba online trade assurance order.

Sample order will be sent within 3 days after receiving sample fee. 3-15 days for general order according to the quantity. Customized order need mutual negotiation.

Sure, We warmly welcome you visit us. Our factory is located in Zhangjiagang City, Jiangsu Province.

Contact Us

Pease allowup to 24hrs.Our agent wilcontact youas soon as possible.