i-anatomical titanium mesh-3D umumo wamafu

Incazelo emfushane:

Isicelo

Ukubuyiselwa nokwakhiwa kabusha kwe-Neurosurgery, ukulungisa ukukhubazeka kwe-cranial, kusiza ukwakha kabusha izidingo ze-cranium eziphakathi nendawo noma ezinkulu.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Okubalulekile:i-titanium ehlanzekile yezokwelapha

Ukucaciswa komkhiqizo

Into No.

Ukucaciswa

12.09.0440.060080

60x80mm

12.09.0440.080120

80x120mm

12.09.0440.090090

90x90mm

12.09.0440.100100

100x100mm

12.09.0440.100120

100x120mm

12.09.0440.120120

120x120mm

12.09.0440.120150

120x150mm

12.09.0440.150150

150x150mm

12.09.0440.150180

150x180mm

Izici Nezinzuzo:

imininingwane (1)

Ukwakhiwa Kabusha Kwedijithali Kogebhezi

Ungqimba oluncane lwe-CT luhlola ugebhezi lwekhanda ngaphambi kokusebenza, ukujiya kongqimba kufanele kube ngu-2.0m.Dlulisa idatha yokuskena endaweni yokusebenza, yenza ukwakhiwa kabusha kwe-3D.Bala umumo wogebhezi, ulingise isici futhi wenze imodeli.Bese wenza isiqephu ngasinye nge-titanium mesh ngokuya ngemodeli.Yenza ukulungiswa kogebhezi lwekhanda ngemva kokuthola imvume yesiguli.

I-3D titanium mesh inobulukhuni obumaphakathi, ukunwebeka okuhle, kulula ukuyimodelisa.Ncoma ukumodela ngaphambi kokuhlinzwa noma kwangaphakathi.

I-3D titanium mesh isebenza kakhulu ukuze ihlangane nesifunda lapho inobuso obugobile obuyinkimbinkimbi noma ijika elikhulu.Ifanele ukubuyiselwa kwengxenye ehlukahlukene yogebhezi.

ukunciphisa isikhathi sokusebenza, ukunciphisa ubuhlungu beziguli, futhi kunciphise ingozi yokuhlinzwa kanye nezinkinga zangemva kokuhlinzwa.Izinkinga zokukhanda ugebhezi ikakhulu ukutheleleka, ukuphuma kwesikhumba ngaphansi kwesikhumba, isilonda esingamahlalakhona esikhumbeni nokunye.Lezi zinkinga zihlobene kakhulu nokunemba kokulungisa izinto zokulungisa.Imiphetho ebukhali ye-titanium mesh ingabangela ubuhlungu besikhumba futhi isike isikhumba, kunzima ukuthi ukugoba okukodwa kwe-titanium mesh kulingane izingxenye ezahlukene zogebhezi.

Idizayini emisha, ekhethekile yasekhaya

yenza i-titanium mesh ibe ngeyakho ngokusho kwe-CT scan yesiguli ngaphambi kokuhlinzwa.Asikho isidingo sokwakhiwa kabusha noma ukusikwa okwengeziwe, i-mesh inomphetho obushelelezi.

inqubo ye-oxidation eyingqayizivele ye-surface hep i-mesh ye-ttanium ithola ubulukhuni obungcono nokumelana.

ibhizinisi elikhethekile lasekhaya elithola isitifiketi sokubhaliswa se-anatomical titanium mesh.

ifu-shape-titanium-mesh-1
ifu-shape-titanium-mesh-2

Ukufanisa isikulufu:

φ1.5mm isikulufu sokuzibhoboza

φ2.0mm isikulufu sokuzibhoboza

Ithuluzi elifanayo:

umshayeli we-screw head screw: SW0.5 * 2.8 * 75mm

isibambo sokuhlanganisa esisheshayo esiqondile

i-cable cutter (i-mesh scissors)

amapulangwe okubumba anezikhala

Imeshi eyakhiwe ngaphambilini iyisixazululo se-anatomic, esilungele ukusetshenziswa sokwakhiwa kabusha kokukhubazeka kobuchopho.Izimila eziyinyumba, esezilungele ukusetshenziswa;izimo ze-anatomic ezisekelwe ocwaningweni lwesayensi nedatha yasemtholampilo;i-contoured ukunciphisa ukugoba & isikhathi senqubo;isisombululo sezomnotho esinemiphumela yobuhle.I-Preformed Mesh ihloselwe ukusetshenziswa ekulungiseni amathambo e-cranial ezinqubweni ezinjengokwakha kabusha, ukulungisa ukuphuka, ama-craniotomies nama-osteotomies.

Isikhathi sokusebenza: Ezinyangeni ezi-3 ngemuva kokukhubazeka kogebhezi, ingcindezi endaweni enesici sogebhezi ayikho phezulu, futhi azikho izici ezingasiza ekwelapheni kokusikwa, njengokutheleleka kanye nesilonda.

Ukulungiselela ngaphambi kokuhlinzwa: Zonke iziguli zazingenakho ukuphikisana nokuhlinzwa, futhi zonke zahlolwa i-CT ye-cranial kanye nokuhlolwa kwe-X-ray yangaphambili.Eqenjini lokubumba idijithali, i-CT scan ye-thince-slice CT scan yenziwa ngokujwayelekile ngogqinsi lwe-2mm, kanye nokwakhiwa kabusha kwe-three-dimensional ithambo langaphambili lenziwa.Khona-ke, i-titanium mesh enezinhlangothi ezimbili yabunjwa "umshini wokubumba wedijithali we-titanium mesh", futhi ukulungiswa kwe-titanium okwenziwe ngezifiso okunezinhlangothi ezimbili kwakuhambisana ngokuphelele nokukhubazeka kwethambo langaphambili lesiguli, elavalwa inzalo ukuze lisetshenziswe kamuva. Kupulasitiki olula we-3D iqembu lokubumba, i-3D elula yepulasitiki ye-titanium mesh engaphezu kuka-2cm enkulu kunomkhawulo wesici ekhethiwe, eyakhiwe ngaphambili ngesikhunta sendabuko futhi yafakwa inzalo ukuze isetshenziswe kamuva.Zonke iziguli zathola i-anesthesia evamile nge-endotracheal intubation kanye nokulungiswa kwembondela.Ngokobukhulu kanye Ukuma kwesici samathambo angaphambili eziguli, iqembu elilula ukuya kwepulasitiki elinezinhlangothi ezintathu lisike inetha le-titanium, labumba mathupha umatha ngangokunokwenzeka ukuze lihlangabezane nezidingo zesizinda esinesici sesiguli, lapholisha unqenqema lalubeka ifasitela lethambo, futhi walilungisa ngesipikili se-titanium esivumelanayo.Ukusetshenziswa njalo kwemithi elwa namagciwane ukuvimbela ukutheleleka, izinsuku ezingu-1 ~ 2 ukususa ishubhu lokudonsa amanzi, izinsuku ezingu-10 ~ 12 ukususa umthungo.Ukuphulukiswa kwesilonda, umphumela wepulasitiki kanye nezinkinga iziguli zazibhekwa isikhathi esifushane ngemva kokuhlinzwa.Ukusebenza kwagcina kuhlolwe ngokwemibandela elandelayo ekulandeleni izinyanga ezingu-3 kamuva.Okuhle kakhulu: ukulungiswa okuthembekile kwepuleti le-titanium alloy mesh, ukubukeka okuhle, akukho zinkinga zangemva kokuhlinzwa;Okuhle: I-Titanium alloy mesh plate ilungiswe ngokuthembekile, izinkinga zangemva kokuhlinzwa zithuthukisiwe ngemva kokwelashwa okubonakalayo;Kunqatshiwe: ukushelela kwe-titanium mesh nokususwa endaweni, noma ukususwa kwe-titanium mesh ngenxa yezinye izinkinga zokuhlinzwa.

Idatha kopisha i-3D CT ngokusemandleni akho ukuze usebenzise ukuskena okungu-1-2 mm, idatha enembe kakhulu ukwenza isifanekiso sinembe kakhudlwana.Ukuze ukopishe idatha, kuyadingeka ukukopisha idatha ye-DICOM yoqobo egumbini le-CT ukuze wonge isikhathi sokucubungula idatha. ukungakopishi idatha yesithombe endaweni yokusebenza, okuzokwenza inqubo ibe nzima kakhulu futhi inganembile kangako.Ibangela ukubambezeleka kwesikhathi noma isikhunta asikwazi ukusetshenziswa.

Izingane zilungisa izindaba ezidinga ukunakwa: 1. Zama ukulalela iseluleko sikadokotela ngezithombe ezimbili ngoba ugebhezi lwezingane lusesigabeni sokukhula kwe-skull gyrus ukukhula izinguquko.Ngoba i-titanium mesh iyinsimbi engeke ikhule, izobangela i-asymmetry logebhezi, oluzothinta ukubukeka nokuthuthukiswa kobuchopho.2.Zama ukusebenzisa i-titanium mesh enezinhlangothi ezintathu, ngoba i-titanium mesh enezinhlangothi ezintathu ithambile futhi inokunwebeka okuthile.Nokho, kufanele sikunake ukuvumela izingane zingenzi ukuvivinya umzimba okukhandla kakhulu ngangokunokwenzeka.


  • Okwedlule: